Menu Close

Tissue Necrosis

The CK-MB Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of human CK-MB in serum, plasma or whole blood, as an aid in the diagnosis of myocardial infarction (MI).

CK-MB is an enzyme also present in the cardiac muscle, with a molecular weight of 87.0 kDa. Creatine Kinase is a dimeric molecule formed from two subunits designated as “M” and “B”, which combine to form three different isoenzymes, CK-MM, CK-BB and CK-MB. CK-MB is the isoenzyme of Creatine Kinase most involved in the metabolism of cardiac muscle tissue. The release of CK-MB into the blood following an MI can be detected within 3 – 8 hours after the onset of symptoms. It peaks within 9 to 30 hours, and returns to baseline levels within 48 to 72 hours.

  • Easy to operate and simple interpretation
  • Room temperature storage or refrigerated (2-30⁰C)
  • Internal control included
  • Cut-off: 5 ng/mL
  • Sensitivity: 93.4%
  • Specificity: 98.7%
  • Specimen: Whole Blood, Serum, Plasma
  • Time to Results: 10 minutes
  • Shelf Life: 24 months from the date of manufacture
Product DescriptionSpecimenCatalog No.FormatCut-off ValueKit Size
CK-MB Rapid Test CassetteS/PGDCKM-302a√Cassette5 ng/mL25 Tests/Kit
CK-MB Rapid Test CassetteWB/S/PGDCKM-402a√Cassette5 ng/mL25 Tests/Kit

√ CE Marked

The Troponin I Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of human cardiac Troponin I in serum, plasma or whole blood, as an aid in the diagnosis of myocardial infarction (MI).

Cardiac Troponin I is a protein found in cardiac muscle, with a molecular weight of 22.5 kDa. Troponin I is part of a three subunit complex comprised of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4 – 6 hours after the onset of pain. The release pattern of Troponin I is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6 – 10 days, thus providing for a longer window of detection for cardiac injury.

  • Easy to operate and simple interpretation
  • Room temperature storage or refrigerated (2-30⁰C)
  • Internal control included
  • Cut-off: 0.5 ng/mL
  • Sensitivity: 96.2%
  • Specificity: 97.0%
  • Specimen: Whole Blood, Serum, Plasma
  • Time to Results: 10 minutes
  • Shelf Life: 24 months from the date of manufacture
Product DescriptionSpecimenCatalog No.FormatCut-off ValueKit Size
Troponin I Rapid Test CassetteS/PGDTRO-302a√Cassette0.5 ng/mL25 Tests/Kit
Troponin I Rapid Test CassetteWB/S/PGDTRO-402a√Cassette0.5 ng/mL25 Tests/Kit
Troponin I Rapid Test CassetteWB/S/PGDTRO-402b√Cassette0.5 ng/mL25 Tests/Kit

√ CE Marked

The Myoglobin Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of human Myoglobin in serum, plasma or whole blood, as an aid in the diagnosis of myocardial infarction (MI).

Myoglobin is a heme-protein normally found in skeletal and cardiac muscle with a molecular weight of 17.8 kDa. It constitutes about 2 percent of total muscle protein and is responsible for transporting oxygen within muscle cells. When muscle cells are damaged, Myoglobin is released into the blood rapidly due to its relatively small size. The level of Myoglobin increases measurably above baseline within 2 – 4 hours post-infarct, peaking at 9 – 12 hours, and returning to baseline within 24 – 36 hours.

  • Easy to operate and simple interpretation
  • Room temperature storage or refrigerated (2-30⁰C)
  • Internal control included
  • Cut-off: 50 ng/mL
  •  Sensitivity: 94.0%
  • Specificity: 95.6%
  • Specimen: Whole Blood, Serum, Plasma
  • Time to Results: 10 minutes
  • Shelf Life: 24 months from the date of manufacture
Product DescriptionSpecimenCatalog No.FormatCut-off ValueKit Size
Myoglobin Rapid Test CassetteWB/S/PGDMYO-402a√Cassette50 ng/mL25 Tests/Kit

√ CE Marked

The Myoglobin/CK-MB/Troponin I Rapid Test is a rapid chromatographic immunoassay for the qualitative detection of human Myoglobin, CK-MB and cardiac Troponin I in serum, plasma or whole blood, as an aid in the diagnosis of myocardial infarction (MI).

Myoglobin (MYO), Creatine Kinase MB (CK-MB) and cardiac Troponin I (cTnI) are proteins released into the bloodstream after cardiac injury. Myoglobin is a heme-protein normally found in skeletal and cardiac muscle with a molecular weight of 17.8 kDa. It constitutes about 2 percent of total muscle protein and is responsible for transporting oxygen within muscle cells. When muscle cells are damaged, Myoglobin is released into the blood rapidly due to its relatively small size. The level of Myoglobin increases measurably above baseline within 2 – 4 hours post-infarct, peaking at 9 – 12 hours, and returning to baseline within 24 – 36 hours.

CK-MB is an enzyme also present in the cardiac muscle, with a molecular weight of 87.0 kDa. Creatine Kinase is a dimeric molecule formed from two subunits designated as “M” and “B”, which combine to form three different isoenzymes, CK-MM, CK-BB and CK-MB. CK-MB is the isoenzyme of Creatine Kinase most involved in the metabolism of cardiac muscle tissue. The release of CK-MB into the blood following an MI can be detected within 3 – 8 hours after the onset of symptoms. It peaks within 9 to 30 hours, and returns to baseline levels within 48 to 72 hours.

Cardiac Troponin I is a protein found in cardiac muscle, with a molecular weight of 22.5 kDa. Troponin I is part of a three subunit complex comprised of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4 – 6 hours after the onset of pain. The release pattern of Troponin I is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6 – 10 days, thus providing for a longer window of detection for cardiac injury.

  • Easy to operate and simple interpretation
  • Room temperature storage or refrigerated (2-30⁰C)
  • Internal control included
  • Cut-off: 50 ng/mL (Myoglobin), 5 ng/mL (CK-MB), 0.5 ng/mL (Troponin I)
  • Sensitivity: 94.0% (Myoglobin), 93.4% (CK-MB), 96.2% (Troponin I)
  • Specificity: 95.6% (Myoglobin), 98.7% (CK-MB), 97.0% (Troponin I)
  • Specimen: Whole Blood, Serum, Plasma
  • Time to Results: 10 minutes
  • Shelf Life: 24 months from the date of manufacture
Product DescriptionSpecimenCatalog No.FormatCut-off ValueKit Size
CK-MB Rapid Test CassetteS/PGDCKM-302a√Cassette5 ng/mL25 Tests/Kit
CK-MB Rapid Test CassetteWB/S/PGDCKM-402a√Cassette5 ng/mL25 Tests/Kit
Myoglobin Rapid Test CassetteWB/S/PGDMYO-402a√Cassette50 ng/mL25 Tests/Kit
Troponin I Rapid Test CassetteS/PGDTRO-302a√Cassette0.5 ng/mL25 Tests/Kit
Troponin I Rapid Test CassetteWB/S/PGDTRO-402a√Cassette0.5 ng/mL25 Tests/Kit
Troponin I Rapid Test CassetteWB/S/PGDTRO-402b√Cassette0.5 ng/mL25 Tests/Kit
Myoglobin/CK-MB/Troponin I Combo Rapid Test CassetteS/PGDCAR-335a√Cassette50/5/0.5 ng/mL25 Tests/Kit
Myoglobin/CK-MB/Troponin I Combo Rapid Test CassetteWB/S/PGDCAR-435a√Cassette50/5/0.5 ng/mL25 Tests/Kit
Myoglobin/CK-MB/Troponin I Combo Rapid Test CassetteWB/S/PGDCAR-W435a√Cassette50/5/0.5 ng/mL20 Tests/Kit

√ CE Marked