Residue Test Strips
A rapid screening test for the qualitative detection of Fentanyl, Xylazine, Benzodiazepine, Carfentanyl,
Medetomidine, Nitazene residue (e.g. dried liquid or powder) on surfaces, including the surface of pills.
This test is used to prevent misuse and overdose deaths of extremely harmful and dangerous drugs.
Features:
- All necessary tools (swabs and buffers) are included in the test kits
- Does not require the crushing of pills and/or dissolving powders to liquids before testing
- Easy collecting and testing procedures
- Easy visual interpretation of results
- Wait time to results: 3-10 minutes
- More sensitive in detection windows than other products
- Most FEN derivatives can be detected with low cut off values
- Carfentanyl has no cross reaction with Fentanyl at < 50,000 ng/ml
- Fentanyl, Nitazene have no cross reactions with Caffeine
- Up to 3 test items in 1 test strip
- This is a non-IVD product
Ordering Information
| Product Description | Catalog No. | Format | Cut-off Value (ng/mL) | Kit Size |
|---|---|---|---|---|
| Fentanyl Test Strip | GBFEN-1001a | Strip | 5 | 3, 5, 20 Tests/Kit |
| Xylazine Test Strip | GBXYL-1001a | Strip | 50 | 3, 5, 20 Tests/Kit |
| Benzodiazepine Test Strip | GBBZO-1001a | Strip | 10 | 3, 5, 20 Tests/Kit |
| Carfentanyl Test Strip | TBC | Strip | 1000 | 3, 5, 20 Tests/Kit |
| Medetomidine Test Strip | GBMDT-1001b | Strip | 100 | 3, 5, 20 Tests/Kit |
| Nitazene Test Strip | GBNTZ-1001Ba | Strip | 100 | 3, 5, 20 Tests/Kit |
| FEN5/XYL50 Combo Test Strip | TBC | Strip | 5 (FEN), 50 (XYL) | 3, 5, 20 Tests/Kit |
| FEN5/XYL50/BZO10 Combo Test Strip | TBC | Strip | 5 (FEN), 50 (XYL), 10 (BZO) | 3, 5, 20 Tests/Kit |
Fentanyl/Xylazine Residue Test Cassette
A rapid screening test for the qualitative detection of Fentanyl, Xylazine, Benzodiazepine, Carfentanyl,
Medetomidine, Nitazene residue (e.g. dried liquid or powder) on surfaces, including the surface of pills.
This test is used to prevent misuse and overdose deaths of extremely harmful and dangerous drugs.
Features
- Integrated buffers and swabs are included in the test kit
- Does not require the crushing of pills and/or dissolving powders to liquids before testing.
- Can easily detect traces by running swab over surface of pills
- Easy collecting and testing procedures
- Easy visual interpretation of results
- Time to results: 5-10 minutes (Do not interpret results after 1 hour)
- Fentanyl/Xylazine can be detected at 5ng/ml and 50 ng/ml respectively.
- More sensitive in detection windows than other products
- Most FEN derivatives can be detected with low cut off values
- 250+ analytes were tested and shown in both IFU
Ordering Information
| Product Description (Combo Test Cassettes) | Catalog No. | Cut-off Value (ng/mL) | Kit Size |
|---|---|---|---|
| FEN5/XYL50 | GBDOA-1025-001 | 5 (FEN), 50 (XYL) | 3, 5, 20 Tests/Kit |
| FEN5/XYL50/BZO10 | TBC | 5 (FEN), 50 (XYL), 10 (BZO) | 3, 5, 20 Tests/Kit |
| FEN5/CFN1000 | GBDOA-1025-002 | 5 (FEN), 1000 (CFN) | 3, 5, 20 Tests/Kit |
| FEN5/XYL50/BZO10/MDT100 | TBC | 5 (FEN), 50 (XYL), 10 (BZO), 100 (MDT) | 3, 5, 20 Tests/Kit |
| FEN5/CFN1000/XYL50/BZO10/MDT100 | TBC | 5 (FEN), 1000 (CFN), 50 (XYL), 10 (BZO), 100 (MDT) | 3, 5, 20 Tests/Kit |






