Residue Test Strips

A rapid screening test for the qualitative detection of Fentanyl, Xylazine, Benzodiazepine, Carfentanyl,
Medetomidine, Nitazene residue (e.g. dried liquid or powder) on surfaces, including the surface of pills.
This test is used to prevent misuse and overdose deaths of extremely harmful and dangerous drugs.

Features:
  • All necessary tools (swabs and buffers) are included in the test kits
  • Does not require the crushing of pills and/or dissolving powders to liquids before testing
  • Easy collecting and testing procedures
  • Easy visual interpretation of results
  • Wait time to results: 3-10 minutes
  • More sensitive in detection windows than other products
  • Most FEN derivatives can be detected with low cut off values
  • Carfentanyl has no cross reaction with Fentanyl at < 50,000 ng/ml
  • Fentanyl, Nitazene have no cross reactions with Caffeine
  • Up to 3 test items in 1 test strip
  • This is a non-IVD product
Ordering Information
Product Description Catalog No. Format Cut-off Value (ng/mL) Kit Size
Fentanyl Test Strip GBFEN-1001a Strip 5 3, 5, 20 Tests/Kit
Xylazine Test Strip GBXYL-1001a Strip 50 3, 5, 20 Tests/Kit
Benzodiazepine Test Strip GBBZO-1001a Strip 10 3, 5, 20 Tests/Kit
Carfentanyl Test Strip TBC Strip 1000 3, 5, 20 Tests/Kit
Medetomidine Test Strip GBMDT-1001b Strip 100 3, 5, 20 Tests/Kit
Nitazene Test Strip GBNTZ-1001Ba Strip 100 3, 5, 20 Tests/Kit
FEN5/XYL50 Combo Test Strip TBC Strip 5 (FEN), 50 (XYL) 3, 5, 20 Tests/Kit
FEN5/XYL50/BZO10 Combo Test Strip TBC Strip 5 (FEN), 50 (XYL), 10 (BZO) 3, 5, 20 Tests/Kit

Fentanyl/Xylazine Residue Test Cassette

A rapid screening test for the qualitative detection of Fentanyl, Xylazine, Benzodiazepine, Carfentanyl,
Medetomidine, Nitazene residue (e.g. dried liquid or powder) on surfaces, including the surface of pills.
This test is used to prevent misuse and overdose deaths of extremely harmful and dangerous drugs.

Features
  • Integrated buffers and swabs are included in the test kit
  • Does not require the crushing of pills and/or dissolving powders to liquids before testing.
  • Can easily detect traces by running swab over surface of pills
  • Easy collecting and testing procedures
  • Easy visual interpretation of results
  • Time to results: 5-10 minutes (Do not interpret results after 1 hour)
  • Fentanyl/Xylazine can be detected at 5ng/ml and 50 ng/ml respectively.
  • More sensitive in detection windows than other products
  • Most FEN derivatives can be detected with low cut off values
  • 250+ analytes were tested and shown in both IFU
Ordering Information
Product Description (Combo Test Cassettes) Catalog No. Cut-off Value (ng/mL) Kit Size
FEN5/XYL50 GBDOA-1025-001 5 (FEN), 50 (XYL) 3, 5, 20 Tests/Kit
FEN5/XYL50/BZO10 TBC 5 (FEN), 50 (XYL), 10 (BZO) 3, 5, 20 Tests/Kit
FEN5/CFN1000 GBDOA-1025-002 5 (FEN), 1000 (CFN) 3, 5, 20 Tests/Kit
FEN5/XYL50/BZO10/MDT100 TBC 5 (FEN), 50 (XYL), 10 (BZO), 100 (MDT) 3, 5, 20 Tests/Kit
FEN5/CFN1000/XYL50/BZO10/MDT100 TBC 5 (FEN), 1000 (CFN), 50 (XYL), 10 (BZO), 100 (MDT) 3, 5, 20 Tests/Kit

Healstone Biotech

UNIT#650-655 West Kent Ave North,
Vancouver, British Columbia, V6P 6T7

1 (604) 800-2434
info.healstone@healgen.com

DISCLAIMER: The health-related information provided on this website is for general information only. It is not intended to serve as medical advice and is not substitute to rely upon in place of a qualified practitioner in your jurisdiction. Healstone Biotech Inc, and its affiliates Healgen Scientific LLC. make every effort to ensure the accuracy and reliability of the information that appears on its website, but cannot guarantee that it is error-free or complete. Please note that actual products may differ slightly from specifications or the pictures. Not everything listed on this website has yet been licensed by Health Canada for sale. Please contact us for more detailed information.